Comply with OSHA Chute (1926.852) and Wall Stability (1926.854) Rules
domain: osha.gov · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗
Steps
For material chutes angled more than 45° from horizontal, fully enclose the chute except for loading openings at/near floor level, and keep openings closed at stories below the top floor when not in use.
Install a substantial gate near the chute's discharge end and assign a competent employee to control it and manage truck loading/backing at the discharge point.
Secure the discharge area when the chute is not in active use, and protect any chute opening where workers dump debris with a guardrail approximately 42 inches above the standing surface.
For wall/masonry removal, ensure no wall section taller than one story is left standing without lateral bracing unless it was originally designed to be self-supporting and confirmed structurally safe.
Leave all walls in a stable condition at the end of every shift, and solidly plank floor openings within 10 feet of a wall being demolished unless employees are excluded from the area below, per 1926.854.
Known gotchas
'Left stable at end of shift' under 1926.854 applies every shift, not just at project completion — a wall temporarily safe mid-shift still needs a stability plan before crews leave for the day.
Falling masonry mass must stay within the floor's safe carrying capacity — demolition sequencing that piles debris faster than it's removed can overload floors even when individual wall-removal steps look compliant.