Determine required interior vapor retarder class by climate zone under IRC R702.7

domain: codes.iccsafe.org · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Confirm that a vapor retarder on the interior side of exterior wood-framed walls is not required in Climate Zones 1-3 under the base provision
  2. Apply the Class I or II vapor retarder requirement for Climate Zones 4 (except Marine 4), 5, 6, 7, and 8 on the interior side of exterior walls per the applicable table
  3. Check whether the specific wall assembly (e.g., with exterior continuous insulation) qualifies for a different/no vapor retarder class under the assembly-specific exception tables
  4. Where a 'responsive' (variable-permeance) vapor retarder is used, confirm it meets both the dry-cup Class I/II criteria and the greater-than-1-perm wet-cup criteria for inward-drying assemblies
  5. Confirm the locally adopted IRC edition, since vapor retarder provisions changed significantly between the 2018 and 2021 IRC

Known gotchas

Related routes

Look up prescriptive insulation R-value and fenestration U-factor requirements by climate zone in the locally adopted IECC
codes.iccsafe.org · 5 steps · unrated
Select and place a vapor retarder under a slab-on-ground per ASTM E1745
vapor-retarders · 5 steps · unrated