File NYC DOB elevator periodic inspection vs Category test reports (ELV3) correctly
domain: nyc.gov — DOB NOW: Safety · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗
Steps
Confirm NYC Building Code requires the device be inspected/tested twice annually: an annual visual Periodic Inspection plus Category testing.
Distinguish Periodic Inspection (annual visual, Jan 1–Dec 31, filed within 14 days) from Category One (CAT1, annual no-load safety test, filed within 21 days) and Category Five (CAT5, 5-year full-load/full-speed test, filed within 21 days).
File the ELV3/ELV3A report through the DOB NOW: Safety portal using an inspection/testing agency independent of the maintenance provider.
Note hard cutoffs: Periodic filings not submitted by Jan 14 of the following year, or CAT1/CAT5 filings not submitted by the 21st day after the deadline month, are rejected outright and trigger failure-to-file violations.
For defects found on CAT1/periodic inspection, correct within 90 days and file an Affirmation of Correction within 14 days of correction; missing the 104-day mark triggers a Failure-to-Correct violation.
Known gotchas
Late fees and failure-to-file/failure-to-correct penalty amounts differ by device class (residential vs non-residential) and filing type — confirm current dollar figures on nyc.gov before quoting them, as they are periodically revised.
The witnessing/testing agency cannot be affiliated with the agency performing maintenance on the same device.