Set up a ladder-jack scaffold within OSHA 1926.452(k) limits

domain: construction-safety.osha-scaffolding · 6 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Confirm platform height will not exceed 20 feet.
  2. Use ladders meeting Subpart X (Stairways and Ladders) requirements; never use a job-made ladder to support a ladder jack.
  3. Confirm the ladder jack bears on both side rails and rungs, or on rungs alone with at least 10 inches of bearing per rung.
  4. Secure ladders against slipping (fasten, tie off, or use anti-slip devices).
  5. Do not bridge platforms between separate ladder jack scaffolds.
  6. Confirm the platform is at least 12 inches wide.

Known gotchas

Related routes

Set up a ladder jack scaffold within OSHA's 1926.452(k) height limit and ladder-support requirements
osha.gov · 6 steps · unrated
Set up a pump-jack scaffold within OSHA 1926.452(j) requirements
construction-safety.osha-scaffolding · 5 steps · unrated
Erect a pump jack scaffold to meet OSHA 1926.452(j) bracket, pole, and bracing requirements
osha.gov · 5 steps · unrated