Specify step and counter flashing replacement (not reuse) at sidewalls and chimneys during a residential reroof.
domain: nrca.net · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗
Steps
Inspect existing step and counter flashing condition at every sidewall and chimney intersection before deciding reuse vs. replacement.
Default to full replacement of step flashing during a reroof, since reusing old step flashing is a common source of leak callbacks and manufacturer warranty denial even where code does not universally mandate replacement.
Verify counter flashing is properly reglet-cut into masonry or lapped under siding/cladding rather than surface-caulked only.
Confirm each step flashing piece is individually woven with the corresponding shingle course, not run as a continuous strip.
Check manufacturer and general NRCA guidance for minimum flashing dimensions and material compatibility, avoiding dissimilar-metal corrosion between flashing and fasteners.
Known gotchas
Some manufacturers' shingle warranties are voided if old flashing is reused during a reroof — check the specific warranty document before deciding to reuse.
Surface-caulked counter flashing (rather than reglet-cut or under-siding) is a common cosmetic shortcut that fails within a few years; don't treat caulk as a substitute for proper mechanical counter flashing.