Disinfect a newly constructed or repaired well following AWWA C654 shock chlorination procedure

domain: awwa.org · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Remove the pump/drop pipe or otherwise expose the casing, gravel pack, and piping to be treated
  2. Calculate the chlorine dose needed based on casing and gravel-pack volume
  3. Introduce chlorine (e.g., calcium or sodium hypochlorite) in the sequence described by AWWA C654: gravel pack, casing, pump, then appurtenant piping
  4. Agitate or circulate the solution and allow adequate contact time before purging
  5. Pump to waste until no detectable chlorine residual remains, then collect a sample for potability testing