Confirm private residence elevator requirements and hoistway door gap hazard rules under ASME A17.1 Section 5.3
domain: asme.org — A17.1 Part 5, Section 5.3 · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗
Steps
Confirm private residence elevators (vertical) are covered by A17.1 Part 5, Section 5.3, distinct from Section 5.4 which covers private residence inclined elevators.
Check for post-2016 hoistway-door/car-door gap provisions intended to prevent small-child entrapment between the hoistway door and car door.
Reference Nonmandatory Appendix H (Private Residence Elevator Guarding, tied to 5.3.1.7.2) for guarding illustration guidance.
Treat any specific numeric gap value (e.g., sill gap, door-to-door gap, ball-reject test dimension) cited in secondary sources as provisional until verified against the exact adopted A17.1 edition text.
Check state/local retrofit mandates separately — retrofit of pre-2016 residential elevators for door-gap compliance is typically driven by state or local amendment, not a uniform federal mandate.
Known gotchas
Secondary sources present slightly different specific gap dimensions — do not state a precise inch figure as authoritative without checking the adopted edition's actual text.
Retrofit obligations for older private residence elevators vary significantly by state/locality — do not assume a nationwide retrofit deadline exists.