Specify and verify ASTM E1155 FF/FL floor flatness and levelness numbers for a slab
domain: flatwork-tolerances · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗
Steps
Confirm the applicable current edition of ASTM E1155 (inch-pound or the E1155M metric companion) directly from ASTM before citing a specific year, since editions are periodically reissued.
Specify separate FF (flatness, based on curvature over a short interval) and FL (levelness, based on differential elevation over a longer interval) numbers appropriate to the floor's use, with higher values for superflat or defined-traffic floors.
Require measurement per the standard's straightedge/wedge or profilograph method, taken within the time window stated in the contract after floor construction.
Define both a specified overall value and a minimum local value in the spec, not just a single target F-number.
Confirm test timing and floor sampling layout are agreed upon at the pre-construction conference so results are not disputed after the fact.
Known gotchas
A single F-number without both a specified overall value and a minimum local value is an incomplete spec and invites disputes.
Profilograph vs. straightedge measurement can yield different results on the same floor -- the contract should name the measurement device/method, not just cite ASTM E1155 generically.