Confirm the roof qualifies as 'low-slope' under OSHA's definition (4-in-12 or less) — steeper roofs fall under a different provision (1926.501(b)(11)) with different requirements
For roof edges 6 feet or more above a lower level, select a compliant fall protection method: guardrail system, safety net system, personal fall arrest system, or an approved combination (warning line + guardrail, warning line + safety net, warning line + PFAS, or warning line + safety monitoring system)
If using a warning line system, position it no less than 6 feet from the roof edge (no mechanical equipment in use) or per the extended distances (6 ft parallel / 10 ft perpendicular to travel direction) when mechanical equipment is being used near the edge
For roofs 50 feet or less in width, confirm eligibility to use a safety monitoring system alone without a warning line, per the narrow-roof exception
Ensure all selected fall protection systems independently meet the detailed criteria in 29 CFR 1926.502 (e.g., guardrail height/strength, PFAS anchorage rating), since 501(b)(10) references 502 for system specifications
Known gotchas
The 50-foot-or-less width exception permits safety monitoring alone only on narrow roofs — it is not a general-purpose exemption from warning lines on wider low-slope roofs
'Low-slope' for OSHA purposes is defined by actual roof pitch (4:12 or less), not by the roof type or membrane — always confirm actual pitch rather than assuming a 'flat roof' label is sufficient
Selecting a fall protection method under 501(b)(10) is not sufficient by itself; the chosen system must also independently satisfy the detailed construction/anchorage criteria in 1926.502