Space control joints in interior gypsum board walls and ceilings per ASTM C840/GA-216

domain: gypsum.org · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Install a control joint where an interior wall or partition runs in an uninterrupted plane exceeding 30 linear feet
  2. For interior ceilings without perimeter relief, limit linear dimension between control joints to 30 ft and total area to 900 sq ft
  3. For interior ceilings with perimeter relief, limit linear dimension to 50 ft and area to 2,500 sq ft
  4. For exterior ceilings/soffits, keep linear dimensions between control joints to 30 ft
  5. Also place control joints at changes in substrate, wall height, or framing type per the assembly drawings

Known gotchas

Related routes

Apply ASTM C840 fastener spacing requirements for screw/nail attachment of gypsum board
astm.org · 5 steps · unrated
Look up a specific UL/GA fire-resistance-rated wall or ceiling assembly design number for a gypsum board partition and confirm its listed STC/fire rating from the current Gypsum Association manual.
gypsum.org / gypsumpublications.com (GA-600 Fire Resistance and Sound Control Design Manual) · 5 steps · unrated
Comply with the ASTM C840/GA-216 50°F minimum temperature requirement for joint treatment and finishing