Apply ASTM C840 fastener spacing requirements for screw/nail attachment of gypsum board

domain: astm.org · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Obtain the current ASTM C840 Standard Specification for Application and Finishing of Gypsum Board
  2. Identify whether the assembly is single-ply or multi-ply and whether framing is wood or steel, since spacing tables vary by application
  3. Apply the maximum on-center fastener spacing from the applicable table for the confirmed framing and ply configuration
  4. Apply nail spacing limits separately from screw spacing where nailing is used
  5. Cross-check spacing against any referenced UL/GA fire-rated assembly design, since listed assemblies can require closer spacing than the base C840 table

Known gotchas

Related routes

Space control joints in interior gypsum board walls and ceilings per ASTM C840/GA-216
gypsum.org · 5 steps · unrated
Install steel framing to receive screw-attached gypsum panels per ASTM C754
astm.org · 5 steps · unrated
Comply with the ASTM C840/GA-216 50°F minimum temperature requirement for joint treatment and finishing