Resolve an AHJ inspection failure over missing per-letter UL labels on a channel letter sign

domain: ul.com · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Confirm the sign is a Class 2-only field-wired multi-piece channel letter sign; under the 2023 UL 48 revision, effective for follow-up inspection instructions on July 1, 2024, such signs are labeled with a single UL Electric Sign mark on the raceway or power-supply enclosure rather than a separate mark on every letter.
  2. If an AHJ fails the inspection for missing per-letter labels, provide documentation that the UL 48 Section Sign definition (Section 2.65) changed and Class 2-only field-wiring no longer requires the old per-piece marking.
  3. Reference the current UL 48 standard, available through UL's free Digital View option, if the AHJ needs a citable source.
  4. Confirm the single mark is actually present on the raceway or enclosure as required, since the rule change removes a labeling burden but not the underlying listing requirement.
  5. Escalate to the manufacturer's UL contact if the AHJ still disputes compliance after documentation is provided.