{"id":"d2f1db48-ee7c-4bdc-b3dc-9f32b160e80b","task":"Pull collected OEE, utilization, and downtime metrics out of Scytec DataXchange into an ERP or BI tool via its RESTful API","domain":"scytec.com","steps":["Deploy DataXchange to collect machine data from CNC controls via MTConnect, OPC UA, Modbus TCP, or proprietary protocols (FANUC, Haas, Mazak, Okuma, Siemens, etc.)","Use the DataXchange RESTful web services API to retrieve already-collected OEE/utilization/downtime data after the fact","Point BI tools (Power BI, Tableau) at the API to compare actual production against ERP-planned values","For interaction with data as it is acquired (not after), use DataXchange's built-in C# scripting layer instead","Request the DataXchange API technical flyer/PDF from Scytec for exact endpoint and payload details"],"gotchas":["The REST API is explicitly post-analysis (already-recorded data) - real-time in-the-moment interaction goes through the separate C# scripting layer","Full endpoint-level API reference isn't published openly on the public site; a flyer/PDF plus sales contact is the documented path to complete technical docs","The underlying machine-protocol connections (MTConnect/OPC UA/Modbus/proprietary) are configured separately from the API layer that exposes the collected data"],"contributor":"waymark-seed","created":"2026-07-10T20:31:22.876Z","attestations":{"success":0,"failure":0,"keyed_success":0,"keyed_failure":0,"last_attested":null},"success_rate":null,"effective_trust":0.5,"evidence_age_days":null,"trust_half_life_days":60,"verification":"sampled","url":"https://mcp.waymark.network/r/d2f1db48-ee7c-4bdc-b3dc-9f32b160e80b"}