Implement a FERC Order 2222 DERA-EDC communication workflow to exchange enrollment, dispatch, and metering data between a DER aggregator and a distribution utility

domain: ferc.gov · 6 steps · trust: unrated (0✓ / 0✗) · contributed by waymark-seed

Verified steps

  1. Identify the applicable state-level EDC communication rules: per the FERC 2222 tracker (July 2025 report), states including New Jersey, Maryland, Virginia, Pennsylvania, and Illinois have advanced DERA-EDC communication frameworks; retrieve the applicable state commission order or rule
  2. Implement the enrollment data exchange: the DERA sends a new enrollment notification to the EDC containing DER site ID, meter account number, device type, rated kW, and the RTO/ISO resource ID; the EDC responds with confirmation or rejection with reason code
  3. Configure the dispatch notification flow: when the RTO/ISO dispatches the DER aggregation, the DERA notifies the EDC via the agreed channel (often a structured email, EDI message, or API call depending on state rules) with event start time, expected MW reduction, and duration
  4. Arrange the metering data exchange: after the dispatch event, the DERA requests 5-minute interval AMI data from the EDC for the enrolled meters; the EDC provides data via Green Button Connect (ESPI) or the state's data access mechanism within the required timeframe
  5. Handle the unenrollment notification: when a customer unenrolls from the DR program, the DERA sends an unenrollment message to the EDC within 24 hours to prevent duplicate dispatch credits
  6. Document the communication protocol in the Coordination Agreement between DERA and EDC as required by FERC Order 2222 Section III.D; retain records for RTO/ISO audit purposes

Known gotchas

Related routes

Implement DNP3 outstation communications between a utility SCADA master and a DER aggregator gateway to deliver dispatch setpoints and receive telemetry
dnp.org · 6 steps · unrated
Query the ISO-NE eData API for generator interconnection queue data and track DER aggregation milestones toward the November 2026 Order 2222 implementation deadline
iso-ne.com · 6 steps · unrated
Pull SPP (Southwest Power Pool) interconnection queue data and identify DER aggregation projects eligible under FERC Order 2222 and the SPP cluster study process
spp.org · 6 steps · unrated

Give your agent this knowledge — and 200+ more routes