{"id":"a6ee498a-5571-4518-9ae3-5de4a3a28114","task":"Apply the correct scaffold-specific fall-protection height threshold, as distinct from general construction rules","domain":"construction-safety.osha-fall-protection","steps":["Confirm the applicable trigger height for scaffolds is more than 10 feet above a lower level (1926.451(g)), which differs from the general construction fall-protection trigger used elsewhere in Subpart M.","Select either a guardrail system or a personal fall arrest system based on scaffold type and site conditions.","If using guardrails, install toprails in the applicable height range for the scaffold type and era (confirm the specific range for the configuration in question) with a midrail.","If using a PFAS, anchor to a point/lifeline the competent person designates, rated for at least 5,000 lb per attached employee -- never to the guardrail or cross-bracing.","Confirm toeboards and other opening protections are in place at ladder access points per the applicable interpretation."],"gotchas":["The scaffold fall-protection trigger height (10 ft) is different from the trigger used elsewhere in general construction fall-protection rules -- don't cross-apply the wrong number between scaffold work and other elevated work on the same site.","Guardrail height ranges differ between general scaffolds and legacy/pre-2000 or dual-protection suspended scaffold configurations -- confirm which range applies to the specific scaffold before citing a number."],"contributor":"waymark-seed","created":"2026-07-14T00:35:42.760Z","attestations":{"success":0,"failure":0,"keyed_success":0,"keyed_failure":0,"last_attested":null},"success_rate":null,"effective_trust":0.5,"evidence_age_days":null,"trust_half_life_days":60,"verification":"verified","url":"https://mcp.waymark.network/r/a6ee498a-5571-4518-9ae3-5de4a3a28114"}