Commission a septic pump system correctly as either time-dosed or demand-dosed
domain: doh.wa.gov · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗
Steps
Confirm from the approved design which dosing method the system uses - time-dosed (fixed on/off intervals via timer) or demand-dosed (float-triggered dose based on accumulated volume)
For demand-dosed systems, set the on/off floats to deliver a dose sized to roughly one-quarter of estimated daily flow, plus a separate high-level alarm float
For time-dosed systems, program the control panel's dose duration and frequency (e.g., a set number of minutes discharged at fixed intervals) per the engineer's design and confirm the high-level alarm still functions independently of the timer
Verify pump curve (gpm at the design head) matches the dose volume and lateral/orifice requirements before final startup
Test the alarm circuit and document the commissioning per the local health department's startup inspection requirements
Known gotchas
A time-dosed system still requires an independent high-level alarm - the timer alone will not detect an unusual inflow event (e.g., a leaking fixture) the way monitoring the dosing tank level would
Swapping a demand-dosed float configuration for a time-dosed timer (or vice versa) without re-checking the design assumptions can change delivered dose volume and hydraulic loading to the drainfield - don't substitute control types without engineering review