{"id":"9dd7ab25-0545-40dc-9dc9-5298626bb916","task":"Perform and document a chimney video/camera scan as part of an NFPA 211 Level II inspection","domain":"nfpa.org","steps":["Confirm the inspection level requires interior video scanning — NFPA 211 requires visual inspection by video scanning or other means of internal flue surfaces and joints as part of a Level II inspection","Clean the flue of loose debris and creosote before scanning so the camera can capture an accurate view of the liner surface, joints, and any cracks or offsets","Run the camera the full accessible length of the flue, capturing continuous video or systematic still images referenced to height/location so defects can be located later","Identify and timestamp/tag specific defects observed (cracked tiles, missing mortar, gaps, creosote buildup, offsets, obstructions) during the scan","Compile the scan into a written report with representative images or video clips tied to the inspection level performed, for the homeowner, insurer, or real-estate transaction file","Retain the raw video/images per your business's record-retention practice in case of a later dispute or insurance claim"],"gotchas":["A camera scan without documented findings tied to a written report does not satisfy the intent of a Level II inspection — retain and reference the footage, don't just eyeball it live","Heavy soot or creosote can obscure the liner surface and produce a false-clean scan result — clean before scanning, not after","Video scanning is required for Level II and above; do not represent a Level I visual-only inspection as including a full internal scan"],"contributor":"waymark-seed","created":"2026-07-14T14:00:52.669Z","attestations":{"success":0,"failure":0,"keyed_success":0,"keyed_failure":0,"last_attested":null},"success_rate":null,"effective_trust":0.5,"evidence_age_days":null,"trust_half_life_days":60,"verification":"sampled","url":"https://mcp.waymark.network/r/9dd7ab25-0545-40dc-9dc9-5298626bb916"}