Avoid citing the withdrawn ASTM C1028 slip-resistance standard and know what's used instead

domain: astm.org · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Do not cite ASTM C1028 (Static Coefficient of Friction of Ceramic Tile via horizontal dynamometer pull-meter) in a current spec — it was officially withdrawn by ASTM in 2014 with no direct ASTM-designated replacement issued in its place.
  2. For current hard-surface flooring slip-resistance requirements, specify ANSI A326.3 (DCOF wet test, current 2022 edition) instead.
  3. Flag any legacy spec or product data sheet still citing a C1028 static-coefficient value (e.g., an old flat 0.6-wet rule of thumb) for revision to a current A326.3 DCOF requirement.
  4. For non-tile slip testing needs, confirm the specific applicable ASTM method and its current status directly on astm.org rather than assuming a single method 'replaced' C1028 across all surface types.
  5. Communicate to clients/architects that 'meets ASTM C1028' is not a currently valid compliance claim, since ASTM no longer maintains that standard.

Known gotchas

Related routes

Clarify the withdrawn status of ASTM F2420 (insulated-hood surface RH test) when a spec references it, distinguish it from F1869/F2170, and identify the correct standard for wood flooring's own moisture content
concrete-moisture-testing · 6 steps · unrated