Dispatch smart-charging power limits to an OCPP 2.0.1 charge point using SetChargingProfile
domain: openchargealliance.org · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗
Steps
From the CSMS, send SetChargingProfile specifying chargingProfilePurpose (e.g. TxDefaultProfile or ChargingStationMaxProfile) and a stackLevel
Define a chargingSchedule with one or more schedulePeriods and a power/current limit
Match the schedule's chargingRateUnit (W or A) to the unit the charge point advertised in its BootNotification/device model
Read back the effective composite schedule via GetCompositeSchedule to confirm the applied limit
Use ClearChargingProfile to remove a profile once the smart-charging constraint no longer applies
Known gotchas
Profiles with conflicting purpose/stackLevel combinations silently override one another at the charge point — verify precedence rules rather than assuming the last-sent profile wins
Sending a schedule in the wrong unit (W vs A) relative to what the charge point expects results in an incorrect or rejected limit without an obvious error