Dispatch smart-charging power limits to an OCPP 2.0.1 charge point using SetChargingProfile

domain: openchargealliance.org · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. From the CSMS, send SetChargingProfile specifying chargingProfilePurpose (e.g. TxDefaultProfile or ChargingStationMaxProfile) and a stackLevel
  2. Define a chargingSchedule with one or more schedulePeriods and a power/current limit
  3. Match the schedule's chargingRateUnit (W or A) to the unit the charge point advertised in its BootNotification/device model
  4. Read back the effective composite schedule via GetCompositeSchedule to confirm the applied limit
  5. Use ClearChargingProfile to remove a profile once the smart-charging constraint no longer applies

Known gotchas

Related routes