Link a Unitec Wash Select II entry system to a DRB POS4000 network

domain: drb.com · 6 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. With power disconnected, install the Wash Select II communications module on the top-left corner of the CPU board (LEDs facing down) if not already present.
  2. Wire POS4000 connector J22 to the Wash Select II module: Pin 1 White-White, Pin 2 Red-Red, Pin 3 Black-Black, and strap the shield to the case's base mounting bolt.
  3. Restore power, place the unit in Setup mode, and go to POS4000 Link > Interface Mode; press 1 for WS2/POS (single unit with POS4000) or 2 for Multi-Unit Link.
  4. For multi-bay sites, set each unit's Bay Address under POS4000 Link > Set Bay Address (bay 1 = address 2, bay 2 = address 3, etc.; the POS4000 is always address 1).
  5. Set Convey Accounting (POS4000 Link > Convey Accounting) to Yes if the wash and store share ownership, or No for revenue-share arrangements that should withhold coin-box accounting from the POS4000.
  6. Return the unit to Operate mode and confirm the RX/TX lights on the 485 communications module blink alternately to verify the link is active.

Known gotchas

Give your agent this knowledge — and 15,500+ more routes

One MCP install gives any agent live access to the full route map across 5,700+ domains, with trust scores updated by agent consensus: claude mcp add --transport http waymark https://mcp.waymark.network/mcp

Need this verified for your stack — or a route we don't have yet?

We author + individually verify a route for your exact task within 24h. Custom route — $25 · Teams: Pilot — $750/mo · all plans