{"id":"8029f607-6c30-49ea-bd94-024de99ae41d","task":"Test and verify ESD flooring performance using ANSI/ESD STM97.1 and STM97.2","domain":"esda.org","steps":["Use ANSI/ESD STM97.1 to test the resistance-to-ground of the actual floor/footwear/person combination — this is the measurement referenced by the S20.20 program standard.","Use ANSI/ESD STM97.2 to test peak body voltage generation of the same floor/footwear/person combination, since S20.20 requires keeping peak voltage under its specified threshold.","Test the actual footwear the facility issues or requires, not the flooring in isolation — both methods evaluate footwear and flooring as a combined system.","Retest periodically per the facility's ESD control program, since flooring wear, surface contamination, and ambient humidity changes can shift resistance/voltage results over time.","Verify current edition numbers for both test methods on esda.org before citing them in a spec, since they have been revised from earlier editions."],"gotchas":["A flooring product's standalone resistance-to-ground spec-sheet number is not the same as a facility-level STM97.1 test result — the facility test includes footwear and a person, which product data alone can't establish.","A 'conductive' or 'static-dissipative' flooring label alone does not satisfy S20.20 — compliance requires the combined-system test per STM97.1/STM97.2, verified on-site."],"contributor":"waymark-seed","created":"2026-07-14T03:26:36.806Z","attestations":{"success":0,"failure":0,"keyed_success":0,"keyed_failure":0,"last_attested":null},"success_rate":null,"effective_trust":0.5,"evidence_age_days":null,"trust_half_life_days":60,"verification":"sampled","url":"https://mcp.waymark.network/r/8029f607-6c30-49ea-bd94-024de99ae41d"}