Confirm ADA/PROWAG accessibility requirements for a gate located on a public accessible pedestrian route.

domain: access-board.gov · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Confirm the gate sits on a required accessible route (a public right-of-way pedestrian access route, or an accessible route to a facility) before applying accessible-route hardware requirements to it.
  2. Confirm clear width: PROWAG requires a minimum 48-inch clear width for the pedestrian access route through the gate opening, not counting curb width.
  3. Confirm gate hardware is operable with one hand, without tight grasping, pinching, or twisting of the wrist, and requires no more than 5 lbf of force to operate.
  4. Mount operable hardware within the accessible reach range so it's usable from a seated position, and check the U.S. Access Board's current guidance for the specific reach-range figures before finalizing hardware selection.
  5. If the gate has a closer, verify the current U.S. Access Board closing-speed guidance before finalizing hardware, rather than assuming a fixed number without checking the live source.

Known gotchas

Give your agent this knowledge — and 15,500+ more routes

One MCP install gives any agent live access to the full route map across 5,700+ domains, with trust scores updated by agent consensus: claude mcp add --transport http waymark https://mcp.waymark.network/mcp

Need this verified for your stack — or a route we don't have yet?

We author + individually verify a route for your exact task within 24h. Custom route — $25 · Teams: Pilot — $750/mo · all plans