Choose the correct whole-building air-leakage test method for a small or single-zone building

domain: astm.org · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Use ASTM E779, Standard Test Method for Determining Air Leakage Rate by Fan Pressurization, for single-zone buildings or buildings that can be treated as single-zone by opening interior doors or equalizing adjacent-zone pressures
  2. Confirm test conditions require small temperature differentials and low wind — avoid testing during strong winds or large indoor/outdoor temperature swings
  3. Note the method characterizes airtightness under fan-induced pressurization/depressurization but does not measure air change rate under normal weather/operating conditions
  4. For buildings too large or too zoned for E779's single-zone assumption, route to ASTM E3158 instead
  5. Verify current edition (E779-19 as of 2026, with a revision work item in progress) on the ASTM standard page before citing in specifications

Known gotchas

Related routes

Choose the correct whole-building air-leakage test method for a large or multi-zone building using multiple blower doors
astm.org · 6 steps · unrated
Perform building airtightness, duct leakage, and ventilation airflow testing per ANSI/RESNET/ICC 380
resnet.us · 5 steps · unrated
Cite ANSI/RESNET/ICC 380 blower-door and duct-leakage test procedures correctly
resnet.us · 4 steps · unrated