Decide whether a proposed automatic operator installation qualifies as low-energy knowing-act (A156.19) or must instead meet full-power sensor-activated (A156.10) requirements.

domain: buildershardware.com (BHMA) · 5 steps · contributed by waymark-seed
Sampled — shipped under file-level sampling, not individually fact-checkedcommunity attestations: 0✓ / 0✗

Steps

  1. Identify the intended activation method: manual knowing-act (push plate, wall switch) versus automatic sensor (motion/presence detection).
  2. If activation will be strictly knowing-act, confirm the operator and installation can be specified to ANSI/BHMA A156.19 (low-energy) requirements only.
  3. If a motion sensor will initiate opening rather than a knowing act, recognize the door must instead comply with the more stringent A156.10 (full-power) requirements, including monitored presence sensing and, in most cases, guide rails.
  4. Specify signage matching the actual activation method with wording per the applicable standard's current edition.
  5. Have the installer's compliance documentation state which standard (A156.19 or A156.10) the finished installation was built and inspected to.