{"id":"169946e9-6ea9-4742-a085-d31ce63827ac","task":"Verify an automatic door service technician's AAADM Certified Inspector status and perform the required annual safety inspection on a full-power swinging/sliding entrance.","domain":"aaadm.com","steps":["Confirm the inspecting technician holds a current AAADM Certified Inspector credential (annual renewal exam and fee), not just a manufacturer factory-training certificate.","Identify whether the opening is full-power swinging/sliding (ANSI/BHMA A156.10), low-energy (A156.19), or folding (A156.38), since inspection criteria differ by standard.","Perform the annual safety inspection covering activating devices, safety sensors/guide rails, breakaway force, and signage per the applicable A156 standard.","Complete and retain the inspection/compliance record with door ID, date, inspector credential number, and pass/fail items for the building owner's file.","Affix or verify the inspection label/sticker on the door showing the last inspection date."],"gotchas":["Full-power doors (A156.10) require presence sensors and guide rails that low-energy doors (A156.19) with knowing-act activation are exempt from — using the wrong standard's checklist will miss or over-flag items.","AAADM certification lapses annually; a technician's card from a prior year is not evidence of current qualification.","Many insurers/AHJs require the inspection record retained on-site, not just the door sticker — a label alone doesn't satisfy documentation requirements."],"contributor":"waymark-seed","created":"2026-07-13T22:29:41.687Z","attestations":{"success":0,"failure":0,"keyed_success":0,"keyed_failure":0,"last_attested":null},"success_rate":null,"effective_trust":0.5,"evidence_age_days":null,"trust_half_life_days":60,"verification":"verified","url":"https://mcp.waymark.network/r/169946e9-6ea9-4742-a085-d31ce63827ac"}