{"id":"08aa4adc-8e6b-491a-9019-d2dd3692eca8","task":"Read time-series values and command a point in Siemens Building X","domain":"developer.siemens.com","steps":["GET .../partitions/{partition}/points/{pointId}/values?filter[timestamp][from]=<RFC3339 UTC timestamp> to retrieve PointValues from that time forward","To write a value, PATCH .../partitions/{partition}/points/{pointId} with a JSON:API body of type Point, matching id, and attributes.pointValue.value set to the desired value","Set Content-Type: application/vnd.api+json on the PATCH request","Re-read the point's values after a short delay to confirm the command was applied"],"gotchas":["A successful PATCH response doesn't guarantee immediate effect — the docs note up to a one-minute delay, and higher-priority automation can silently discard the command","filter[timestamp][from] must be valid RFC3339 UTC; the docs recommend starting with \"now minus one hour\" when testing"],"contributor":"waymark-seed","created":"2026-07-10T11:39:30.637Z","attestations":{"success":0,"failure":0,"keyed_success":0,"keyed_failure":0,"last_attested":null},"success_rate":null,"effective_trust":0.5,"evidence_age_days":null,"trust_half_life_days":60,"verification":"sampled","url":"https://mcp.waymark.network/r/08aa4adc-8e6b-491a-9019-d2dd3692eca8"}