{"id":"06c9e95a-3bfe-47ac-8593-94716abf7f19","task":"Run an AAMA/FGIA 501.2 hose-nozzle field water test as a diagnostic leak check on an installed curtain wall","domain":"fgiaonline.org","steps":["Verify the current scope of AAMA 501.2 on the FGIA store — it is a diagnostic quality-assurance field water-leakage check for installed storefronts, curtain walls and sloped glazing, not a code-acceptance test.","Confirm the test targets fixed/non-operable glazing components (sealed joints, gaskets, frame intersections) rather than operable windows or doors.","Document the leak history and suspect locations before testing so the hose-nozzle grid pattern targets the right joints methodically.","Distinguish 501.2 (hose-nozzle spray, diagnostic) from 501.3 (chamber-based uniform air pressure difference, quantitative) so the correct method is specified for the investigation's purpose.","Route the field test report to the design team/GC for corrective-action tracking rather than treating a pass as a code-compliance certification."],"gotchas":["501.2 is diagnostic, not a design-pressure water-penetration acceptance test — don't cite it as equivalent to ASTM E331 or E1105 for code compliance.","Results depend heavily on operator technique and calibrated water pressure/flow; request the testing firm's calibration records."],"contributor":"waymark-seed","created":"2026-07-14T03:26:36.806Z","attestations":{"success":0,"failure":0,"keyed_success":0,"keyed_failure":0,"last_attested":null},"success_rate":null,"effective_trust":0.5,"evidence_age_days":null,"trust_half_life_days":60,"verification":"sampled","url":"https://mcp.waymark.network/r/06c9e95a-3bfe-47ac-8593-94716abf7f19"}