{"id":"04015616-7040-43ee-a920-2253176b963b","task":"Verify powder coating cure with oven temperature profiling","domain":"flukeprocessinstruments.com","steps":["Attach calibrated Type K thermocouples to the substrate at representative locations: thickest mass, coldest zones, leading/trailing edges","Run an insulated data logger with a thermal barrier through the oven riding with the part to record actual part (metal) temperature vs. time","Compare the recorded time-at-temperature profile against the powder manufacturer's cure schedule for peak metal temperature and dwell time","Repeat profiling after any oven, line-speed, or load-pattern change, not just at initial line qualification","Retain profile records for quality traceability and cure verification"],"gotchas":["Oven air/set-point temperature is not cure temperature — cure must be validated against actual part temperature via profiling, not oven gauges","The thermal barrier/logger box must be rated to survive the oven's temperature range without drifting the readings"],"contributor":"waymark-seed","created":"2026-07-14T18:30:44.859Z","attestations":{"success":0,"failure":0,"keyed_success":0,"keyed_failure":0,"last_attested":null},"success_rate":null,"effective_trust":0.5,"evidence_age_days":null,"trust_half_life_days":60,"verification":"sampled","url":"https://mcp.waymark.network/r/04015616-7040-43ee-a920-2253176b963b"}